logo
Startseite ProdukteWiderstrebende Lasts-Bank

KW2800 Resistive Inductive Load Bank

Bescheinigung
CHINA Qingdao Kingway Industry Co., Ltd. zertifizierungen
CHINA Qingdao Kingway Industry Co., Ltd. zertifizierungen
Ich bin online Chat Jetzt

KW2800 Resistive Inductive Load Bank

KW2800 Resistive Inductive Load Bank
KW2800 Resistive Inductive Load Bank KW2800 Resistive Inductive Load Bank

Großes Bild :  KW2800 Resistive Inductive Load Bank

Produktdetails:
Herkunftsort: China
Markenname: KINGWAY
Zertifizierung: CE, ISO
Modellnummer: KL280
Zahlung und Versand AGB:
Min Bestellmenge: 1 Satz
Preis: usd14,000.00
Verpackung Informationen: Holzkiste
Lieferzeit: 14 Tage
Zahlungsbedingungen: L/C, T/T
Versorgungsmaterial-Fähigkeit: 20 Einheiten/Monat

KW2800 Resistive Inductive Load Bank

Beschreibung
Portabilität: Tragbar oder stationär Anwendung: Generatorprüfung
Kontrollkraft: 380 VAC 50 Hz Tragfähigkeit: Variiert (z. B. 10 kW bis 2000 kW)
Nennflüchtigkeit: 400 V Farbe: Maßgeschneidert
Hitze-Streuung: Luftkühlung

1.1 Foreword

(1) According to the special requirements of users on site, in the agreement the technical standards of KW2800(2800KW/3500KVA) Resistive Inductive Load Bank (hereinafter referred to as "system") and its accessories are proposed including their function, performance, usage, structure, installation and test to provide users with a high efficient and reliable choice, in order to meet the need for generator load test.

(2) The system consists of 1 sets of 3500KVA Load Bank, The resistive power is 2800KW, the inductive power is 2100KVAR. The system is made up of two parts of measurement & control and load, mainly including the medium voltage dry type AC load bank, automatic data acquisition system, automatically loading and unloading control system, the cooling device, auxiliary control, remote control box and PC software and so on.

(3)This system, which is of independent research and development of electricity load test equipment by our technology, combining high voltage dry type load module with the automatic measurement and control module, with excellent insulation protection performance, it can detect generator output power and load capacity, full load and overload test.

The system can be used with a computer to realize the intelligent control, automatically completing the special test to all electrical parameters of generating set and generating tables, graphs, and supporting the print, release from the cumbersome manual operation to provide scientific and efficient detection means for the large power high voltage generating sets.

(4) All the schematic diagrams of this agreement are for reference only please in kind prevail.

1.2System Characteristics

1.2.1 The system is a self-developed device used for electricity load testing by KINGWAY Technology. It perfectly combines the high voltage dry type load module and measurement and control module, precisely test output power and load performance of kinds of generator set.

System mainly consists of resistance load, data collecting, control system, cooling device, etc. The system can test output power and load performance of generator sets.

1.2.2 System can load power in rated range, measure generator steady-state 3 phase voltage, current, active power, power factor, frequency, and running time, and simulate the generator set real load working state. Power input using sectional type, energy dissipation type load, forced-air cooling, 3 phase fan decentralized supply air, air-flow is sufficient and low noise.

1.2.3 System can work with PC software to realize intelligent operation, automatically finish the parameters testing, and create testing data table, curves and reports that can be printed, reduce a lot of manual operation.

 

Rating voltage/frequency 400V, 3 phase 4 wire 50Hz
Max Load Power Apparent Power: 3500KVA
  Resistive Load: 2800KW
  Inductive Load: 2100KVAR
Load Resolution Resistive Load: 22 steps 1KW,2KW,2KW,5KW,10KW,10KW,20KW,50KW,100KW,200KW,200KW,200KW,200KW,200KW,200KW,200KW,200KW,200KW,200KW,200KW, 200KW, 200KW,
  Inductive Load: 19 steps
  1KVAR,2 KVAR, 2KVAR, 5KVAR, 10KVAR, 10KVAR, 20KVAR, 50KVAR, 100KVAR,100KVAR, 200KVAR, 200KVAR, 200KVAR, 200KVAR, 200KVAR,200KVAR,200KVAR,200KVAR,200KVAR
Power Factor 0.8(lag)
Load Tolerance (each step) ±5%
Load Tolerance (overall) ±3%
Fan &Control Voltage External AC 3 phase 4 line, 380V/50Hz
Wire Connection Load bank input——Copper bar (star coupling ”Y”)
  Control power input——Connector-bar
Communication Interface RS485,RS232
Insulation F
Max Protection Grade IP54
Duty Cycle Continuous
Cooling Forced air cooling, by Axial Fan; horizontal inlet air, vertical exhaust cooling
Enclosure Container type,with a ladder, air inlet and outlet with mesh enclosure and protection door
Internal Lighting Adequate internal lighting will be provided
Transportation Hoisting, there are lifting lug in top of casing
Color Grey RAL7035 or as required
Dimensions 6058mm×2350mm×2591mm(L×W×H)
Operating Environment Parameter  
Workplace Outdoor
Ambient Temperature -10+50
Relative Humidity ≤95%
Atmospheric Pressure 86106kPa
Brands of Main Components  
Contactor Schneider
Fuse Miro
Alloy Resistor KINGWAY
Data Processing Software KINGWAY

 

 

KW2800 Resistive Inductive Load Bank 0KW2800 Resistive Inductive Load Bank 1KW2800 Resistive Inductive Load Bank 2KW2800 Resistive Inductive Load Bank 3

Kontaktdaten
Qingdao Kingway Industry Co., Ltd.

Ansprechpartner: Mr. Bruce Jia

Telefon: +8618653247836

Faxen: 86-532-55718566

Senden Sie Ihre Anfrage direkt an uns (0 / 3000)