logo
Startseite ProdukteGas-Generator

Kingway KW2800 Intelligent Resistive and Inductive Load Bank for Generator Testing, Containerized AC Power Loadcenter

Bescheinigung
CHINA Qingdao Kingway Industry Co., Ltd. zertifizierungen
CHINA Qingdao Kingway Industry Co., Ltd. zertifizierungen
Ich bin online Chat Jetzt

Kingway KW2800 Intelligent Resistive and Inductive Load Bank for Generator Testing, Containerized AC Power Loadcenter

Kingway KW2800 Intelligent Resistive and Inductive Load Bank for Generator Testing, Containerized AC Power Loadcenter
Kingway KW2800 Intelligent Resistive and Inductive Load Bank for Generator Testing, Containerized AC Power Loadcenter Kingway KW2800 Intelligent Resistive and Inductive Load Bank for Generator Testing, Containerized AC Power Loadcenter Kingway KW2800 Intelligent Resistive and Inductive Load Bank for Generator Testing, Containerized AC Power Loadcenter Kingway KW2800 Intelligent Resistive and Inductive Load Bank for Generator Testing, Containerized AC Power Loadcenter Kingway KW2800 Intelligent Resistive and Inductive Load Bank for Generator Testing, Containerized AC Power Loadcenter Kingway KW2800 Intelligent Resistive and Inductive Load Bank for Generator Testing, Containerized AC Power Loadcenter Kingway KW2800 Intelligent Resistive and Inductive Load Bank for Generator Testing, Containerized AC Power Loadcenter

Großes Bild :  Kingway KW2800 Intelligent Resistive and Inductive Load Bank for Generator Testing, Containerized AC Power Loadcenter

Produktdetails:
Herkunftsort: China
Markenname: Kingway Power
Zertifizierung: CE, ISO
Modellnummer: KL280
Zahlung und Versand AGB:
Min Bestellmenge: 1 Satz
Preis: usd14,000.00
Verpackung Informationen: Holzkiste
Lieferzeit: 14 Tage
Zahlungsbedingungen: L/C, T/T
Versorgungsmaterial-Fähigkeit: 20 Einheiten pro Monat

Kingway KW2800 Intelligent Resistive and Inductive Load Bank for Generator Testing, Containerized AC Power Loadcenter

Beschreibung
Portabilität: Tragbar oder stationär Anwendung: Generatorprüfung
Kontrollkraft: 380 VAC 50 Hz Tragfähigkeit: Variiert (z. B. 10 kW bis 2000 kW)
Nennflüchtigkeit: 400 V Farbe: Maßgeschneidert
Hitze-Streuung: Luftkühlung

Kingway KW2800 Intelligent Resistive and Inductive Load Bank for Generator Testing, Containerized AC Power Loadcenter

Kingway KW2800 Intelligent Resistive and Inductive Load Banks are engineered to provide reliable, high-capacity power testing solutions for demanding industrial applications. By utilizing advanced digital control and precision measurement technology, our systems deliver optimized commissioning and performance verification for diverse power sources, including diesel generators, gas generator sets, and autonomous micro-grids, ensuring absolute grid stability and operational safety.

As a fully Containerized AC Power Loadcenter, this heavy-duty unit integrates robust cooling architectures, precision alloy resistors, inductive elements, and intelligent remote-monitoring systems. Every unit is custom-calibrated to match specific testing environments and high-voltage/low-voltage configurations, significantly reducing commissioning risks and downtime while maximizing long-term return on investment for critical power infrastructure.

Technical Specifications

Rating Voltage / Frequency 380V/50Hz
Max Load Power Inductive Load: 2100KVAR
Load Resolution

Resistive Load: 22 steps (1KW, 2KW, 2KW, 5KW, 10KW, 10KW, 20KW, 50KW, 100KW, 200KW, 200KW, 200KW, 200KW, 200KW, 200KW, 200KW, 200KW, 200KW, 200KW, 200KW, 200KW, 200KW)


Inductive Load: 19 steps (1KVAR, 2 KVAR, 2KVAR, 5KVAR, 10KVAR, 10KVAR, 20KVAR, 50KVAR, 100KVAR, 100KVAR, 200KVAR, 200KVAR, 200KVAR, 200KVAR, 200KVAR, 200KVAR, 200KVAR, 200KVAR, 200KVAR)

Power Factor 0.8 (lag)
Load Tolerance Each step: ±5% | Overall: ±3%
Fan & Control Voltage External AC 3 phase 4 line, 380V/50Hz
Wire Connection

Load bank input——Copper bar (star coupling "Y")

Control power input——Connector-bar

Communication Interface RS485, RS232
Insulation / Protection Insulation: F | Max Protection Grade: IP54
Cooling System Forced air cooling, by Axial Fan; horizontal inlet air, vertical exhaust cooling
Enclosure & Dimension

Container type, with a ladder, air inlet and outlet with mesh enclosure and protection door


Dimensions: 6058mm × 2350mm × 2591mm 

Environment Parameter -10+50
Brands of Main Components Contactor: Schneider | Fuse: Miro | Alloy Resistor: KINGWAY | Data Processing Software: KINGWAY

Why Choose Our Power Systems?

  • Tailored Load Configuration: Custom-engineered resistive and inductive element steps to perfectly match specific generator testing requirements and diverse power factor  calibrations.


  • Intelligent System Integration: Full integration of high-end components—including Schneider contactors, Miro fuses, and KINGWAY proprietary alloy resistors—housed in a rugged IP54 container to ensure maximum stability under harsh outdoor environments.


  • High ROI: Highly precise digital measurement and intelligent remote-monitoring systems prevent costly testing downtime, providing fast, accurate commissioning data that shortens project payback periods.


  • Full-Lifecycle Support: Comprehensive, long-term availability of original spare parts paired with advanced KINGWAY remote technical diagnostic and data processing software services.


Primary Applications

  • Data Centers & Critical Infrastructure: Providing high-capacity, multi-step load testing for standby diesel generators and UPS systems to guarantee zero-downtime power backup.
  • Marine & Offshore Engineering: Rigorous commissioning and load verification of shipboard generators and offshore platform power plants under simulated heavy-duty sea conditions, compliant with LR/DNV/BV standards.

  • Oil & Gas Operations: Reliable on-site electrical load testing for localized micro-grids, field power stations, and turbine generators in demanding oilfields and remote drilling operations.

  • Renewable Energy & Micro-Grids: Performance validation and stress-testing of hybrid power systems, including energy storage systems (ESS), wind, solar, and biomass autonomous grids.

Frequently Asked Questions (FAQ)

Q1: How do I choose the correct generator for my gas source?

A: Gas composition and pressure are critical. Please provide a gas analysis report (including H2S content), and our engineering team will suggest the optimal model.

Q2: Can the generator operate in extreme temperatures?

A: Yes, we provide custom cooling systems, including specialized radiators or heat exchangers, for operational environments ranging from -40°C to +50°C.

Q3: How often is maintenance required?

A: Maintenance cycles depend on gas quality. We provide a tailored maintenance schedule and digital monitoring tools to track performance and predict service intervals.


Kingway KW2800 Intelligent Resistive and Inductive Load Bank for Generator Testing, Containerized AC Power Loadcenter 0

Kingway KW2800 Intelligent Resistive and Inductive Load Bank for Generator Testing, Containerized AC Power Loadcenter 1

Kingway KW2800 Intelligent Resistive and Inductive Load Bank for Generator Testing, Containerized AC Power Loadcenter 2

Kingway KW2800 Intelligent Resistive and Inductive Load Bank for Generator Testing, Containerized AC Power Loadcenter 3

Kontaktdaten
Qingdao Kingway Industry Co., Ltd.

Ansprechpartner: Mr. Bruce Jia

Telefon: +8618653247836

Faxen: 86-532-55718566

Senden Sie Ihre Anfrage direkt an uns (0 / 3000)